All Topics | Topic: “Pumped storage HPP”
Author Message
Ms. Tina Dasic
Subject: Pumped storage HPP   
Posted: 9/21/2016 Viewed: 16550 times

Dear all,

I would like to know how to add pumped storage hydro-power plant (with upper and lower reservoirs) into WEAP. Is it possible?

Thanks in advance,
Tina
Ms. Stephanie Galaitsi
Subject: Re: Pumped storage HPP   
Posted: 9/27/2016 Viewed: 16467 times

Dear Tina,

If my understanding is correct, the model would either have to assume some sort of uniformity in periods of low electrical demand, or it would have to have a model for it. I can help you with the first option, since WEAP can manage that based on the time step scale. To model that, you would two reservoirs, and have a transmission link between them with rules about how much water is transferred and under what conditions. The demand priority of the upper reservoir would have to be higher than the priority of the lower reservoir.

Are you modeling electricity usage? You can try reading through the WEAP-LEAP tutorial (the last chapter of the WEAP tutorial) to get a sense of how that can be done in WEAP.