All Topics |
    Topic: “CALIBRATION PROBLEMS”
  
  
  
    
  
  
  | Author | Message | 
|---|
| 
             
              Subject: CALIBRATION PROBLEMS    
            Posted: 9/10/2018 Viewed: 13382 times 
              I noticed that one cannot calibrate Prefered flow direction using pest?  
           | 
        
| 
             
              Subject: Re: CALIBRATION PROBLEMS    
            Posted: 9/12/2018 Viewed: 13371 times 
              Did you get an error?  
           | 
        
| 
             
              Subject: Re: CALIBRATION PROBLEMS    
            Posted: 10/6/2018 Viewed: 13327 times 
              It is not even available in the options to calibrate also Runoff Resistance Factor is not there  
           | 
        
| 
             
              Subject: Re: CALIBRATION PROBLEMS    
            Posted: 10/6/2018 Viewed: 13325 times 
              These two variables are only available at the lowest level branches within a catchment.  For example, if you have a catchment named "Farm," which has two branches, "Irrigated" and "Rainfed," then Runoff Resistance Factor and Preferred Flow Direction exist for the "Irrigated" and "Rainfed" branches, but not on the "Farm" branch.  Therefore, when you are calibrating with PEST, you must choose the lowest level branch so that you can choose Runoff Resistance Factor or Preferred Flow Direction.
  
          Jack  | 
        
| 
             
              Subject: Re: CALIBRATION PROBLEMS    
            Posted: 10/9/2018 Viewed: 13000 times 
              Thanks so much Jack I am grateful  
           | 
        