All Topics |
Topic: “CALIBRATION PROBLEMS”
Author | Message |
---|
Subject: CALIBRATION PROBLEMS
Posted: 9/10/2018 Viewed: 12623 times
I noticed that one cannot calibrate Prefered flow direction using pest?
|
Subject: Re: CALIBRATION PROBLEMS
Posted: 9/12/2018 Viewed: 12612 times
Did you get an error?
|
Subject: Re: CALIBRATION PROBLEMS
Posted: 10/6/2018 Viewed: 12568 times
It is not even available in the options to calibrate also Runoff Resistance Factor is not there
|
Subject: Re: CALIBRATION PROBLEMS
Posted: 10/6/2018 Viewed: 12566 times
These two variables are only available at the lowest level branches within a catchment. For example, if you have a catchment named "Farm," which has two branches, "Irrigated" and "Rainfed," then Runoff Resistance Factor and Preferred Flow Direction exist for the "Irrigated" and "Rainfed" branches, but not on the "Farm" branch. Therefore, when you are calibrating with PEST, you must choose the lowest level branch so that you can choose Runoff Resistance Factor or Preferred Flow Direction.
Jack |
Subject: Re: CALIBRATION PROBLEMS
Posted: 10/9/2018 Viewed: 12241 times
Thanks so much Jack I am grateful
|
Topic: “CALIBRATION PROBLEMS”