All Topics | Topic: “Calibration and Validation”
Author Message
Dr. Olivier Ndayitegeye
Subject: Calibration and Validation   
Posted: 8/24/2022 Viewed: 7748 times

Dear All, Could anyone tell me what is the best way of calibrating and validating WEAP, between the Parameter Estimator Tool (PEST) and WEAP model Inspector tool, and why? Thanks in advance.

Mr. Jack Sieber
Subject: Re: Calibration and Validation   
Posted: 10/26/2022 Viewed: 7426 times

The new version of WEAP (2022.0) can calculate calibration statistics, such as Nash-Sutcliffe Efficiency, Percent Bias and r^2, comparing modeled results to historical data for streamflow, reservoir storage and catchment snow accumulation, to aid in model calibration.

See https://www.weap21.org/WebHelp/Calibration_Statistics.htm for more information.

Jack
Mr. Doug Chalmers
Subject: Re: Calibration and Validation   
Posted: 2/5/2025 Viewed: 2859 times

For those wondering-

In general, the PEST calibration tool is built right into WEAP and is faster to learn and use. On the other hand, the Model Inspector tool has more features to compare run results.

To access model inspector, it is available under the description of the Youtube video lesson: https://www.youtube.com/watch?v=vn6MRbOTVA4&list=PLoJ3pxCzMP1uQRaimYV-wxJRRuIMNzdVU&index=13