Welcome to WEAP's Website WEAP
WEAP is an initiative of the Stockholm Environment Institute.


About WEAP

Home
Why WEAP?
Features
What's New?
Sample Screens
Demonstration
Publications
History and Credits

Using WEAP
Download
Licensing
User Guide
Tutorial
Videos (YouTube)

User Forum
Discussions
Members List
Edit Profile

Additional Support
Training
University Courses
Collaboration

About Us
SEI-US Water Resources Program
Please Contact Us

LEAP
Interested in Energy?
Read about LEAP: SEI's software for energy planning.

Link WEAP and LEAP for combined Water-Energy planning.
Watch a video demo!
   

User Forum

All Topics | Topic "Water Demand WEAP result varying from manual test calculation"
Log in to post new messages or reply to existing messages.
 
Author Message
Ms. Anabel Matalanga

Subject: Water Demand WEAP result varying from manual test calculation   
Posted: 8/30/2024 Viewed: 827 times
Hi there,
I inputted the following for water demand.

Activity level (population): Rural - 16,970; Urban - 7,085
Water Use: Rural - 57; Urban - 128

Result: 1,870,203
Manual Calculation: 1,870,207

Although the variation is relatively small, what may cause it?
Mr. Doug Chalmers

Subject: Re: Water Demand WEAP result varying from manual test calculation   
Posted: 9/6/2024 Viewed: 509 times
Anabel,

If I calculate 16970*57 + 7085*128 then I am getting 1,874,170. Am I mistakened somewhere?
Ms. Anabel Matalanga

Subject: Re: Water Demand WEAP result varying from manual test calculation   
Posted: 10/1/2024 Viewed: 114 times
Oh yes, this is right, however, in WEAP, the result is less. May you kindly assist with why this is? My NRW is 25%. Otherwise, I have not managed to identify any other variable that may be causing this.
Mr. Doug Chalmers

Subject: Re: Water Demand WEAP result varying from manual test calculation   
Posted: 10/1/2024 Viewed: 105 times
Anabel,

So are you receiving a water demand of 1,870,203 result in WEAP, versus the manual calculation of 1,874,170?

What is the supply requirement result?