Subject: Irrigaiton Fraction Posted: 12/22/2015 Viewed: 14869 times
Hellow WEAP users
I cited from WEAP user guide
Runoff = Max (0, Precipitation available for ET – potential ET)
+ Precipitation*[effective precipitation]
+ Supply*[1- Irrigation Fraction]
This function for Rainfall Runoff Method.
In WEAP interface, where I can modify "irrigation fraction"?
And what is definition of HU - hydro unit in WEAP?
Thank you !
Irrigation fraction is the percentage of the supplied water available for ET consumption (i.e., irrigation efficiency). When using the Rainfall Runoff (soil moisture model), you can select whether to have irrigated areas in your catchment by right-clicking on the catchment in the schematic, going to "General Info" and checking "includes irrigated areas". Once that button has been clicked, you will see an additional tab for data entry in your catchment element called "Irrigation". The first sub-category is % of irrigated area ("Irrigated Area).
Where do you see mention of HU?
Mr. Pham Quoc
Subject: Re: Irrigaiton Fraction Posted: 12/30/2015 Viewed: 14776 times
Thank you so much for your meticulous instruction.
It's very useful to me.
I see "HU" in the WEAP manual, in the Runoff Algorithm Calculation part.(Along with notation "LC"-land Cover)
Ms. Stephanie Galaitsi
Subject: Re: Irrigaiton Fraction Posted: 12/30/2015 Viewed: 14764 times
Looks like it is "hydro-unit" (HU can sometimes also mean the Heat Unit).
Mr. Quoc Pham
Subject: Re: Irrigaiton Fraction Posted: 12/31/2015 Viewed: 14753 times
Yes, but in this case, what does "hydro - unit" mean in WEAP?
Mr. Jack Sieber
Subject: Re: Irrigaiton Fraction Posted: 12/31/2015 Viewed: 14748 times
Hydro unit, an abbreviation of hydrological unit, is a catchment.
Mr. Quoc Pham
Subject: Re: Irrigaiton Fraction Posted: 12/31/2015 Viewed: 14743 times
Thank you Jack !
It's clear